Model | FS-N41C*1 | |||
Type | M8 Connector*2 | |||
Main unit/expansion unit | Main unit | |||
Response time | 23 µs (S-HSPD*3) /50 µs (HSPD*4) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) | |||
Number of control outputs | 2*5 | |||
Number of external inputs | 1*5 | |||
Light source LED | Transmitter side: Red, four-element LED (wavelength: 660 nm) | |||
Control output | Open-collector, 30 V or less 100 mA or less per output, | |||
External input | Input time: 2 ms (ON) /20 ms (OFF) or longer*6 | |||
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection | |||
Mutual interference prevention | S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) | |||
Power supply | Power voltage | 10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*7 | ||
Power consumption | During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) | |||
Environmental resistance | Ambient light | Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less | ||
Ambient temperature | -20 °C -4 °F to +55 °C +131 °F (no freezing)*9 | |||
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes | |||
Shock resistance | 500 m/s2; 3 times each for X, Y, and Z axes | |||
Case material | Main unit and cover: polycarbonate | |||
Weight | Approx. 25 g | |||
*1 IO-Link Specifi cation V.1.1/COM2 (38.4 kbps) is supported. |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


FS-N41N
Subscribe to get pricesModel: FS-N41N
Order No: FS-N41N
SKU: 10000008551501
Condition: New Sealed Under Guarantee
Size: 100.00 mm,120.00 mm,25.00 mm
Weight: 0.02kg
Product Selection Engineer:Lan
Brief Introduction
FS-N41N
ModelFS-N41C*1TypeM8 Connector*2Main unit/expansion unitMain unitResponse time23 µs (S-HSPD*3) /50 µs (HSPD*4) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputs2*5Number of external inputs1*5Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)Control outputOpen-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)Residual voltageNPN 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA)PNP 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*6Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*7Power consumptionDuring normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*9Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 25 g*1 IO-Link Specifi cation V.1.1/COM2 (38.4 kbps) is supported.*2 Ensure the cable length is 30 m 98.4" or less for the M8 connector type. Ensure the cable length is 20 meters 65.6' or less when connecting by way of IO-Link.*3 Restrictions when S-HSPD is selectedOutput 2 of dual output types is fixed to OFF.IO-Link communication cannot be used.Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*4 Restrictions when HSPD is selectedDisplay Gain cannot be used.*5 Output 2 and the external input are selectable.*6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*9 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
Description
Subscription successful
Price list will be sent to you by email within 24hrs.